Parker Series C10C*E 2-Way Slip-In Cartridge Valve

The 2/2 way seat valves series C10 C*E in cartridge design are equipped with an inductive switch to monitor the closed position. They are preferably used for safety-relevant applications.

Get a quick quote

It is convenient for our customer service staff to contact you in time
Click or drag a file to this area to upload.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump

Parker 2/2-way seat valves series C10C*E in slip-in cartridge design are the preferred choice for safety-relevant applications because they enable a reliable shut-off and safe hold of loadings. C10 valves are equipped with an inductive switch to monitor the closed position. The poppet has a 60/40 area ratio (AA = 0.6 AC, AB = 0.4 AC) and is capable for flow in both directions.

The safety overlap of the poppet avoids opening of the valve before the signal of the inductive switch has changed. For sizes NG80 and NG100 a proximity switch is used.

Markets:

• Industrial

Benefits:

• Cavity and mounting pattern according to ISO 7368 – for quick, easy integration
• 8 sizes, NG16 up to NG100 – allows extremely variable use
• Poppet with safety overlap – guaratees safe switching
• Short delivery time for most sizes – no warehousing necessary
• Cover to mount a directional control valve (on the side) for cover 3 (only for sizes NG16 to NG63, not included in the delivery)
• Monitored closed position
• Inductive switch CE conform
• Optionally with poppet sealing between pilot flow C and port B

Applications:

• Suitable for general hydraulic applications
• General presses
• Die cast

 

Mounting Type  Slip-in cartridge
Actuation Type  Oil pilot
Product Series  Seat valve
Weight  Depending on size, 1.5 to 89.0 kg
Maximum Flow Rate  Depending on size, 230-7500 L/min
Maximum Operating Pressure  350 bar
Maximum Operating Temperature  60 °C
Minimum Operating Temperature  -20 °C
Seal Material  NBR, FPM
For Fluid Type  Hydraulic oil according to DIN 51524, Water glycol
Function  Normally closed, 2-way
Configuration  N/A
Operation Type  Hydraulically
Flow Rate  N/A
Body Material  Steel / cast iron (cover)

Parker Series C10C*E 2-Way Slip-In Cartridge Valve Service Manual

 

    Parker Series C10CE 2-Way Slip-In Cartridge Valve Service Manual

 

 

 

Scroll to Top

Get A Quick Quote

It is convenient for our customer service staff to contact you in time
Click or drag a file to this area to upload.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump
contact us