Parker Series R5U Pilot Operated Pressure Unloading Valve, SAE Flange
Parker pilot operated pressure unloading valves series R5U are particularly suitable for unloading a circuit at low pressure. The SAE flanges allow to mount the valve directly on the outlet flanges of pumps to achieve a very compact design.
Get a quick quote
Pilot operated pressure unloading valves series R5U are exceptional – both in function and design – even under high flow conditions. They are part of the Parker valve range with SAE flanges which is unique in its variety. Series R5U has a similar design to the subplate mounted R4U series.
R5U valves are used to unload a circuit at low pressure. The SAE flange allows to mount the valve directly on the outlet flanges of pumps. A typical application is the unloading of pumps in an accumulator circuit. The combination of an R5U, C5V and R5V on a double pump generates a high pressure/low pressure system without the need of a manifold block or piping between the valves. The R5U is optionally available with a vent function for unpressurized circulation.
Markets:
• Industrial
Benefits:
• Maximum adjustable pressure of 350 bars and flow capacity ranging from 90 l/min to 600 l/min – high performance
• Sophisticated pilot stage design – reduces pressure overshoot and cracking flow to a minimum, thus reducing heating, power and production losses in high pressure operation
• Design combines a poppet type seat valve with the pilot control – precise adjustment and quick response to eliminate pressure variation and system shocks
• Short delivery time – no warehousing necessary
• 3-port body with SAE61 flange – enables compact design
• 4 sizes (SAE ¾”, 1″, 1¼”, 1½”)
• 3 pressure stages
• 3 adjustment modes
– Hand knob
– Acorn nut with lead seal
– Cylinder lock
• With optional vent function
Applications:
• Suitable for general hydraulic applications
Technical Specifications
Body Type | 3-port, M, Y1, X = G 1/4 |
Flange Size | SAE61 |
Frequency | N/A, 50/60 Hz |
Mounting Type | Flanged according to SAE61 |
Operation Type | Pilot |
Actuation Type | Solenoid, Manually |
Product Series | Pressure valve |
Weight | Depending on size, 3.6 – 9.7 kg |
Maximum Operating Pressure | Depending on size, 280 – 350 bar |
Maximum Pressure Setting | 105, 210, 350 bar |
Flow Rate | Depending on size, 90 – 600 L/min |
Maximum Flow Rate | N/A L/min |
Seal Material | NBR, FPM |
Maximum Operating Temperature | 60 °C |
Minimum Operating Temperature | -20 °C |
For Fluid Type | Hydraulic oil according to DIN 51524, Water glycol |
Body Material | Cast iron |
Parker Series R5U Pilot Operated Pressure Unloading Valve, SAE Flange Service Manual