With flow rates up to 9500 l/min and fast response times, proportional throttle valves series TEA are predestined for injection molding and die cast applications. The directional valve integrated in the pilot circuit provides the safety function.
Get a quick quote
Parker’s proportional throttle valves in cartridge design with shut-off valve series TEA combine high flow and fast response times and thus provide high efficiency. These accumulator discharge valves are preferably used in hydraulic systems where high flow rates are discharged from hydraulic accumulators over a short operating period (in the range of milliseconds).
Typical applications are injection molding and die cast machines as well as hydraulic presses. Basically the function of an accumulator discharge valve corresponds to the function of a TDA throttle valve. In addition a directional valve is integrated in the pilot circuit to meet the relevant safety regulations.
Markets:
• Industrial
• Molding
Benefits:
• Cavity and mounting pattern according to ISO 7368 – for quick, easy integration
• Maximum operating pressure up to 350 bar – suitable for demanding hydraulic applications
• High flow rates up to 9500 l/min – enables efficient operation
• Various sizes, NG25 – NG100 – allows extremely variable use
• Short delivery time for most sizes – no warehousing necessary
Applications:
• General presses
• Injection molding
• Die cast
Safety function:
The directional valve provides the safety function. When the solenoid is deenergized and the spring is in end position, pilot pressure from X presses the control piston into lower end position and the main poppet is closed. As a result the flow from B to A or from the reservoir system to the machine is blocked.
Technical Specifications
Product Series | Throttle valve |
Operation Type | Pilot |
Actuation Type | Proportional |
Function | 2-way |
Mounting Type | Slip-in cartridge |
Mounting Position | Unrestricted |
Configuration | N/A |
Maximum Operating Pressure | 350 bar |
Minimum Pilot Pressure | > 25 % of system pressure |
Maximum Flow Rate | Depending on size, 500 – 9500 L/min |
Flow Rate | N/A |
Flow Direction | A to B, B to A |
Maximum Operating Temperature | 60 °C |
Minimum Operating Temperature | -20 °C |
Seal Material | NBR, FPM |
For Fluid Type | Hydraulic oil according to DIN 51524, Water Glycol |
Weight | Depending on size, 7.5 to 85 kg |
Body Material | Steel/Cast iron (cover) |
Parker Series TEA Proportional Throttle Valve with Shut-Off Valve Service Manual
Parker Series TEA Proportional Throttle Valve with Shut-Off Valve Service Manual
Related products
-
Hydraulic Valves
Parker D1VC, D1VD, D1VG Series Cam Operated Directional Control Valve
Rated 0 out of 5Read more -
Hydraulic Valves
Parker Series D1FP / D3FP Direct Operated Proportional Directional Control Valve
Rated 0 out of 5Read more